1/4" FNPT x 1/4" FNPT 20 psi Fixed High Pressure Regulator
Unit of Measure

Purchasing Info

QTY Avbl For Sale

N/A {-}

BEN

N/A {-}

FLI

N/A {-}

GOL

N/A {-}

LEE

N/A {-}

Stock Class

N/A {-}

QB5

N/A {-}

QB4

N/A {-}

QB3

N/A {-}

QB2

N/A {-}

QB1

N/A {-}

UOM

N/A {-}

Specifications

Brand

N/A Marshall Excelsior (MEC™)

Inlet Connection Size

N/A 1/4 in

Inlet Connection Thread Type

N/A Female National Pipe Thread (FNPT)

Outlet Connection Size

N/A 1/4 in

Outlet Connection Thread Type

N/A Female National Pipe Thread (FNPT)

Pressure Setting

N/A 20 psig

Exterior Finish

N/A Red Powder Coat

Pressure

N/A 20 psi

Note

Note

N/A Approximate Btu/hr capacities vary on inlet pressure and outlet set point, taking 10-20 % drop into consideration. Side outlet connection style (plugged): 1/4" Male National Pipe Thread (MNPT), pressure gauge (MEJ500 Series) can be installed.

Liquefied Petroleum Gas (LPG) Capacities (Vapor)

Outlet Set Point

N/A 15 psi20 psi40 psi50 psi

Inlet Pressure for 15 psi Outlet Set Point

N/A 20 psi100 psi150 psi

Inlet Pressure for 20 psi Outlet Set Point

N/A 50 psi100 psi

Inlet Pressure for 40 psi Outlet Set Point

N/A 100 psi150 psi

Inlet Pressure for 50 psi Outlet Set Point

N/A 100 psi150 psi200 psi

Liquefied Petroleum Gas (LPG) Vapor Capacity at 15 psi Outlet Set Point and 50 psi Inlet Pressure

N/A 850,000 Btu/hr

Liquefied Petroleum Gas (LPG) Vapor Capacity at 15 psi Outlet Set Point and 100 psi Inlet Pressure

N/A 1,700,000 Btu/hr

Liquefied Petroleum Gas (LPG) Vapor Capacity at 15 psi Outlet Set Point and 150 psi Inlet Pressure

N/A 2,500,000 Btu/hr

Liquefied Petroleum Gas (LPG) Vapor Capacity at 20 psi Outlet Set Point and 50 psi Inlet Pressure

N/A 900,000 Btu/hr

Liquefied Petroleum Gas (LPG) Vapor Capacity at 20 psi Outlet Set Point and 100 psi Inlet Pressure

N/A 1,800,000 Btu/hr

Liquefied Petroleum Gas (LPG) Vapor Capacity at 40 psi Outlet Set Point and 100 psi Inlet Pressure

N/A 1,500,000 Btu/hr

Liquefied Petroleum Gas (LPG) Vapor Capacity at 40 psi Outlet Set Point and 150 psi Inlet Pressure

N/A 2,000,000 Btu/hr

Liquefied Petroleum Gas (LPG) Vapor Capacity at 50 psi Outlet Set Point and 100 psi Inlet Pressure

N/A 1,300,000 Btu/hr

Liquefied Petroleum Gas (LPG) Vapor Capacity at 50 psi Outlet Set Point and 150 psi Inlet Pressure

N/A 1,800,000 Btu/hr

Liquefied Petroleum Gas (LPG) Vapor Capacity at 50 psi Outlet Set Point and 200 psi Inlet Pressure

N/A 2,300,000 Btu/hr

Proposition 65 Information

N/A

WARNING: This product can expose you to one or more chemicals known to the state of California to cause cancer, birth defects or reproductive harm. For more information, go to www.p65warnings.ca.gov