Fitting and Pipe Nipple Kit
Unit of Measure

Purchasing Info

QTY Avbl For Sale

N/A {-}

BEN

N/A {-}

FLI

N/A {-}

GOL

N/A {-}

LEE

N/A {-}

Stock Class

N/A {-}

QB5

N/A {-}

QB4

N/A {-}

QB3

N/A {-}

QB2

N/A {-}

QB1

N/A {-}

UOM

N/A {-}

Specifications

Brand

N/A RMI

Gauge Included

N/A No

Fitting Package

N/A RMI Part Numbers KCT12-10 1/2" K Copper Tubing 10', NS4I 5/8" Flare Short Forged Nuts, 103-16 1" 45° Elbow Steel Fitting, 106-1612 1" x 3/4" Forged Hex Bushing, 107-1208 3/4" x 1/2" Reducer Coupling, 109-16 1" Steel Union Sch 80, 124-03 3/4" x 3" Nipple Sch 80 , 125-03 1" x 3" Nipples Sch 80, 48IK Male Connectors, 125-09 1" x 9" Nipple Sch 80, 150-2016 1-1/4" x 1" Concentric Swage , 104-16 1" 90° Elbow Steel Fitting, 125-02 1" x 2" Nipple Sch 80

Kit Includes

N/A Key - 2
RMI Part Number - 104-16
1" - 90º Elbow

Key - 2
RMI Part Number - 125-02
1" X 2" Nipple

Key - 3
RMI Part Number - 103-16
1" 45º Elbow

Key - 4
RMI Part Number - 125-03
1" X 3" Nipple

Key - 7
RMI Part Number - 109-16
1" Union

Key - 8
RMI Part Number - 125-09
1" X 9" Nipple

Key - 8
RMI Part Number - 150-2016
1-1/4" X 1" Concentric Swage

Key - 9
RMI Part Number - 106-1612
1" X 3/4" Hex Bushing

Key - 11
RMI Part Number - 124-03
3/4" X 3" Nipple

Key - 11
RMI Part Number - 107-1208
3/4" X 1/2" Reducer Coupling

Key - 17
RMI Part Number - (2) 48IK
5/8" X 3/4 " Flare Fittings

Key - 17
RMI Part Number - KCT12-10
Copper Tubing-Type K, 10 ft.

Key - 17
RMI Part Number - (2) NS4I
5/8" Flare Nuts

General Design Principles for Fill Stations

General Design Principles for Fill Stations

N/A
  1. An adequate size storage tank free of sediment and scale must be supported by a stable and sturdy mounting stand mounted as high above the pump as practical. The assembly must be properly grounded.
  2. Heavy-duty schedule 80 pipe and fittings are required with an excess flow valve at the tank, and a strainer and a flex connector in the line to protect the piping and pump.
  3. The pump should be located under the tank with a short, direct line of adequate size to supply the pump. This inlet line should never rise up to the pump.
  4. The pump and motor must be properly sized to provide the capacity desired. A by-pass valve set at approximately 100 psi must be used and the by-pass line must have sufficient capacity to handle flow returning to tank.
  5. Proper selection of a meter requires many considerations including capacity of the system and the meter features desired. Vapor line from vapor eliminator on the meter to a vapor opening on the tank must be free of scale and have no dips in the pipe.
  6. Sufficiently sized hose and hose valve are necessary for the capacity required and must be protected by an excess flow valve. Filler couplings and adapters must be selected to allow filling of the various type containers.
  7. Safety considerations at the fill station should include a break-a-way coupling, fire extinguisher and proper warning and instructional signs.

Proposition 65 Information

N/A

WARNING: This product can expose you to one or more chemicals known to the state of California to cause cancer, birth defects or reproductive harm. For more information, go to www.p65warnings.ca.gov