Complete Valve Kit
Unit of Measure

Purchasing Info

QTY Avbl For Sale

N/A {-}

BEN

N/A {-}

FLI

N/A {-}

GOL

N/A {-}

LEE

N/A {-}

Stock Class

N/A {-}

QB5

N/A {-}

QB4

N/A {-}

QB3

N/A {-}

QB2

N/A {-}

QB1

N/A {-}

UOM

N/A {-}

Specifications

Brand

N/A RMI

Gauge Included

N/A Yes

Fitting Package

N/A RMI Part Numbers FLEX 1-12 Double Braid Flex Connector 1" x 12", GB-400 0-400# Pressure Gauge, ME390 POL Filler Coupling, ME392 FPOL x QCC (Type1) Adapter, ME449 3/4" NPT Transfer Valve, ME880-6/14 3/4" Excess Flow Valve 14 gpm, ME880-6/22 3/4" Excess Flow Valve 22 gpm, ME202 1/4" Snubber, FH-1218 1/2 Hose 3/4" x 1/2" MPT Ends 18', ME652S 1" Y Strainer 40 Mesh Screen, MEH225 1/4" Hydrostatic Relief 440 psig, ME568 1-3/4 F ACME x FPOL Swivel, C407M10-04 1-1/4" Internal Valve with P341 Latch Release, ME791CJ 1/2" x 1/4" Non-Locking Toggle Valve with Bleeder

Kit Includes

N/A Key - 1
RMI Part Number - C407M-10-03
Tank Valve with Relief

Key - 5
RMI Part Number - ME652S
Strainer

Key - 6
RMI Part Number - FLEX 1-12
Flex Connector

Key - 10
RMI Part Number - ME880-6/22
Excess Flow Valve

Key - 14
RMI Part Number - FH-1218
1/2" Hose with ends 18 ft.

Key - 15
RMI Part Number - ME791C
Hose End Valve

Key - 15
RMI Part Number - ME390
POL Filler Coupling

Key - 15
RMI Part Number - 901H
Adapter

Key - 15
RMI Part Number - ME392
Adapter

Key - 16
RMI Part Number - ME449
Transfer Valve

Key - 16
RMI Part Number - ME880-6/14
Excess Flow Valve

Key - 16
RMI Part Number - MEH225
Relief Valve

Key - 18
RMI Part Number - ME202
Snubber

Key - 18
RMI Part Number - GB-400
Pressure Gauge

General Design Principles for Fill Stations

General Design Principles for Fill Stations

N/A
  1. An adequate size storage tank free of sediment and scale must be supported by a stable and sturdy mounting stand mounted as high above the pump as practical. The assembly must be properly grounded.
  2. Heavy-duty schedule 80 pipe and fittings are required with an excess flow valve at the tank, and a strainer and a flex connector in the line to protect the piping and pump.
  3. The pump should be located under the tank with a short, direct line of adequate size to supply the pump. This inlet line should never rise up to the pump.
  4. The pump and motor must be properly sized to provide the capacity desired. A by-pass valve set at approximately 100 psi must be used and the by-pass line must have sufficient capacity to handle flow returning to tank.
  5. Proper selection of a meter requires many considerations including capacity of the system and the meter features desired. Vapor line from vapor eliminator on the meter to a vapor opening on the tank must be free of scale and have no dips in the pipe.
  6. Sufficiently sized hose and hose valve are necessary for the capacity required and must be protected by an excess flow valve. Filler couplings and adapters must be selected to allow filling of the various type containers.
  7. Safety considerations at the fill station should include a break-a-way coupling, fire extinguisher and proper warning and instructional signs.

Proposition 65 Information

N/A

WARNING: This product can expose you to one or more chemicals known to the state of California to cause cancer, birth defects or reproductive harm. For more information, go to www.p65warnings.ca.gov