PK-D2 Valve Package
Unit of Measure

Purchasing Info

QTY Avbl For Sale

N/A {-}

BEN

N/A {-}

FLI

N/A {-}

GOL

N/A {-}

LEE

N/A {-}

Stock Class

N/A {-}

QB5

N/A {-}

QB4

N/A {-}

QB3

N/A {-}

QB2

N/A {-}

QB1

N/A {-}

UOM

N/A {-}

Specifications

Brand

N/A Blackmer® RMI

Gauge Included

N/A Yes

Fitting Package

N/A RMI Part Number - C407M-10-03
Tank Valve with Relief

RMI Part Number - ME652S
Strainer

RMI Part Number - 105-12
3/4" Hex Plug

RMI Part Number - FLEX 1-12
Flex Connector

RMI Part Number - ME202
Snubber

RMI

Kit Includes

N/A Key - 7
RMI Part Number - ME870-6
3/4 in. Back Check

Key - 9
RMI Part Number - MEN401-06
3/4 in. Angle Valve

Key - 10
RMI Part Number - MEJ602H
1/4 in. Elbow with Relief and Bleed

Key - 12
RMI Part Number - ME880-6/22
Excess Flow Valve

Key - 14
RMI Part Number - FH-1218
3/4 in. 90º Elbow

Key - 15
RMI Part Number - LPGH-3/4-3C
3/4 in. x 3 ft. Hose with Ends

Key - 16
RMI Part Number - ME860S-6
3/4 in. Break-A-Way Coupling

Key - 17
RMI Part Number - ME791CJ
Toggle with bleeder

Key - 18
RMI Part Number - G-820
POL Filler Coupling

Key - 19
RMI Part Number - C407M-10-03
Tank Valve with Relief

Key - 21
RMI Part Number - ME652S
Strainer

Key - 22
RMI Part Number - FLEX 1-12
Flex Connector

Key - 23
RMI Part Number - ME449
Transfer Valve

Key - 24
RMI Part Number - MEH225
1/4 in. External Relief Valve

Key - 25
RMI Part Number - ME880-6/14
Excess Flow Valve

Key - 26
RMI Part Number - BL-4-4LP
1/4 in.F x 1/4 in.M Street Elbow

Key - 27
RMI Part Number - ME202
Snubber

Key - 28
RMI Part Number - GB400
Pressure Gauge

General Design Principles for Fill Stations

General Design Principles for Fill Stations

N/A
  1. An adequate size storage tank free of sediment and scale must be supported by a stable and sturdy mounting stand mounted as high above the pump as practical. The assembly must be properly grounded.
  2. Heavy-duty schedule 80 pipe and fittings are required with an excess flow valve at the tank, and a strainer and a flex connector in the line to protect the piping and pump.
  3. The pump should be located under the tank with a short, direct line of adequate size to supply the pump. This inlet line should never rise up to the pump.
  4. The pump and motor must be properly sized to provide the capacity desired. A by-pass valve set at approximately 100 psi must be used and the by-pass line must have sufficient capacity to handle flow returning to tank.
  5. Proper selection of a meter requires many considerations including capacity of the system and the meter features desired. Vapor line from vapor eliminator on the meter to a vapor opening on the tank must be free of scale and have no dips in the pipe.
  6. Sufficiently sized hose and hose valve are necessary for the capacity required and must be protected by an excess flow valve. Filler couplings and adapters must be selected to allow filling of the various type containers.
  7. Safety considerations at the fill station should include a break-a-way coupling, fire extinguisher and proper warning and instructional signs.

Note

Note

N/A All items listed above come in assembled cabinet, scale needs to be ordered separately.
This package is available assembled with a steel or aluminum cabinet. Contact RMI Customer Service for details.

Proposition 65 Information

N/A

WARNING: This product can expose you to one or more chemicals known to the state of California to cause cancer, birth defects or reproductive harm. For more information, go to www.p65warnings.ca.gov